• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large tear drop shaped jaws.
Kyoritsu 2002R Digital Clamp Meter
• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large tear drop shaped jaws.
• High sensitivity, miniature AC/DC clamp meter.
• 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
• Output terminal for recorder connection.
Kyoritsu 2031 Digital Mini Clamp Meter
• Can measure large AC current up to 200A.
• 24mm-dia tear drop shaped jaws.
- Designed to meet international safety standard IEC 61010-1 CAT.IV 600V
|
|
|
|
Thus, very useful for power distribution companies, power utilities and maintenance fields. |
Kyoritsu 2055 Digital Clamp Meter
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
Kyoritsu 2056R Digital Clamp Meter
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.
• Ultra Slim and lightweight Handy design
• 1000A AC Clamp Meter AC40/400/1000A Auto Range
• Ø33mm Tear Drop Jaw easy to use in tight places
• DMM function ACV, DCV, Ω, Continuity Buzzer
• Fuseless electronic protection on up Ω/ to 600V
• IEC61010-1 Safety Standard
CAT III 600V (AC A) CAT III 300V / CAT II 600V (AC/DC V)
• Ultra slim and lightweight Handy design
• Ø33mm Tear Drop Jaw easy to use in tight places
• 1000A AC Clamp Meter
• DMM function ACV, DCV, Ω, Continuity Buzzer
• Fuseless electronic protection on "Ω/Continuity Buzzer" up to 600V
• Safety Standard IEC 61010-1, 61010-2-032 CAT IV 300V / CAT III 600V
• Flexible and light weight clamp sensor
• Wide reading range up to 3000A
• True RMS
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V / CAT III 1000V)
• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal.
• Resolution 0.1mA.
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables an accurate measurement for distorted waveforms.
• Measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2 way analogue output terminal
• Resolution 0.1mA
-
True RMS for accurate readings on distorted waveforms.
-
Auto-ranging and data hold for ease of use.
-
Backlit display for low-light conditions.
• High Sensitive Model
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
• 0.01mA resolution for DC current
• Top class measurement 0.2% accuracy
• Ø6mm clamp jaw easy to use in tight places
• Measurement from 0.01mA to 120.0mA
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span
• Spotlight for illuminating measurement point
• Analog output terminal for recorder connection
• Complies with IEC 61010-1 CAT II 300V