• Adaptor designed to increase the measuring capability of your clamp meters.
• With the use of the multi-tran you can not only extend current ranges but also on a conductor of larger diameter.
Kyoritsu 1009 Digital Multimeter(1009)
• Display : 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Resistance range provides audible continuity test.
• Automatically turns power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster.
Kyoritsu 1011 Digital Multimeter
• Temperature measurement, selectable for ºC and ºF
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation
• True RMS can measure and indicate distorted waveforms
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation
Kyoritsu 1018 Digital Pocket Multimeter
• Display : 4000 counts.
• Auto range.
• Diode test feature.
• Capacitance test feature.
• Continuity test.
• Display : 4000 counts.
• Auto range.
• Diode test feature.
• Capacitance test feature.
• Continuity test.
• Elegant shiny-black finish
• Comes with user-friendly Hard case
• Large Display
• Accurate reading with True-RMS technology
• Electronic protection (no fuse!) on ohm and continuity ranges
• Safety Standard IEC 61010-1 / 61010-031 / 61010-2-033 CAT III 300V / CAT II 600V
Kyoritsu 1021R Digital Multimeter
• Elegant and easy-to-use cabinet
• Large display with 6000 counts and Backlight
• Enhanced current measuring function using an external clamp sensor
• Two detachable holders, flat and wing type
• Accurate reading with True RMS
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
• Compact in Size, Light in Weight and Simple in Use.
• Double moulding provides comfortable and good feeling in hand.
• Penlight illuminates brightly the point to be measured, even in dark place.
• Backlight LCD is highly visible, even in darkness.
• Unique wrapping mechanism for test lead in the rear side compartment.
• Unique protection mechanism for the test prod for safety.
• All ranges including Ohm range are protected against overload voltage of 600V.
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• Low-pass filter for motor drive measurements
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• True-RMS or MEAN value detection mode can be selected
• Low-pass filter for motor drive measurements
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC
Reliable support for data management
• Large data internal memory 1,600 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
*MAX 32,767 data can be transferred.
High Accuracy, High Performance and Reliable Measurements
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Fast Peak Hold response time of 250µs
Safety design for industrial use
• Complies with IEC 61010-1 CAT III 1000V, CAT IV 600V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
• Large data internal memory
KEW 1061: 1,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.
High Accuracy, High Performance and Reliable Measurements
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Wide AC Frequency bandwidth from 10Hz to 100kHz
• True-RMS or MEAN value detection mode can be selected
• Fast Peak Hold response time of 250µs
• Low-pass filter for motor drive measurements
• Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT III 1000V, CAT IV 600V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
• Large data internal memory
KEW 1062: 10,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.
• Mirrored scale for easy and accurate reading.
• Output terminal to cut off DC component when measuring AC voltage.
• Safety designed input terminals and test leads.
• High sensitivity DC20kΩ/V.
• 1m drop-proof heavy duty designed taut-band movement.
• Can measure line voltage up to AC 600V.
(Voltage to ground MAX AC300V)
(Protected by 600V ceramic fuse against accidental overload)
• Continuity buzzer, battery check, LED check, temperature
measurement function.
• Skeleton type robust and clear case
with carrying handle furnished as standard accessory.
• Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
• Capable of measuring AC and DC currents up to 100A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large tear drop shaped jaws.
Kyoritsu 2002R Digital Clamp Meter
• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large tear drop shaped jaws.
• Equipped to measure both AC and DC current with transformer jaws of large diameter.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.
• CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
• Accurate True-RMS reading of AC current or voltage with distorted waveform.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.
• High sensitivity, miniature AC/DC clamp meter.
• 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
• Output terminal for recorder connection.
• Tear drop shaped jaws for ease of use in tight places and crowded cable areas.
• Designed to meet internationally proven safety standards such as IEC 61010-1, UL3111 and VDE0411.
• Three functions in one unit; AC current, AC voltage and resistance.
• Resistance range provides audible continuity test.
• Frequency response from 40Hz to 1kHz on AC current and voltage ranges.
Kyoritsu 2027 Digital Clamp Meter
• True RMS reading instrument that permits precise measurements of nonsinusoidal waveform AC current and voltage. Accurate measurements are also possible at low frequencies from 10Hz upwards.
• Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
• Three functions in one unit; AC current, AC voltage and resistance.
Kyoritsu 2031 Digital Mini Clamp Meter
• Can measure large AC current up to 200A.
• 24mm-dia tear drop shaped jaws.
Kyoritsu 2033 Digital Clamp Meter
• Smallest clamp meter capable of AC and DC current measurements.
• 300A auto ranging has minimum resolution of 0.01A AC/DC.
• Auto-zero function to allow one touch zero adjustment.
- Designed to meet international safety standard IEC 61010-1 CAT.IV 600V
|
|
|
Thus, very useful for power distribution companies, power utilities and maintenance fields. |
Kyoritsu 2046R Clamp Meter (True RMS)
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.
Kyoritsu 2055 Digital Clamp Meter
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
Kyoritsu 2056R Digital Clamp Meter
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.
Kyoritsu 2117R Digital Clamp Meter
• Fully Safety jaw
• Ergonomic over-molded body gives convenient one-hand operation
• Large easy-to-read display with 0.01A resolution
• Accurate reading with True RMS
60/600/1000A auto-ranging
• Long battery life
• Safety Standard
IEC 61010-1 CAT IV 300V / CAT III 600V
• Ultra Slim and lightweight Handy design
• 1000A AC Clamp Meter AC40/400/1000A Auto Range
• Ø33mm Tear Drop Jaw easy to use in tight places
• DMM function ACV, DCV, Ω, Continuity Buzzer
• Fuseless electronic protection on up Ω/ to 600V
• IEC61010-1 Safety Standard
CAT III 600V (AC A) CAT III 300V / CAT II 600V (AC/DC V)
• Ultra slim and lightweight Handy design
• Ø33mm Tear Drop Jaw easy to use in tight places
• 1000A AC Clamp Meter
• DMM function ACV, DCV, Ω, Continuity Buzzer
• Fuseless electronic protection on "Ω/Continuity Buzzer" up to 600V
• Safety Standard IEC 61010-1, 61010-2-032 CAT IV 300V / CAT III 600V
• Flexible and light weight clamp sensor
• Wide reading range up to 3000A
• True RMS
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V / CAT III 1000V)
Kyoritsu 2300R Digital Fork Current Tester
• True RMS reading is an essential feature for accurate measurement.
• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
• Set the DC current range to zero in one touch with the Zero Adjust function.
• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal.
• Resolution 0.1mA.
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables an accurate measurement for distorted waveforms.
• Measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2 way analogue output terminal
• Resolution 0.1mA
Kyoritsu 2431 Leakage Digital Clamp Meter
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges 20mA/200mA/200A.
• Rotary switch for easy one finger power-on and range selection.
• Resolution 0.01mA.
• High Sensitive Model
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA
Kyoritsu 2433 Leakage Digital Clamp Meter
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
• 0.01mA resolution for DC current
• Top class measurement 0.2% accuracy
• Ø6mm clamp jaw easy to use in tight places
• Measurement from 0.01mA to 120.0mA
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span
• Spotlight for illuminating measurement point
• Analog output terminal for recorder connection
• Complies with IEC 61010-1 CAT II 300V
Kyoritsu 3005A Insulation/Continuity Tester
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
Kyoritsu 3007A Insulation/Continuity Tester
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Trac-Lok mode to conserve battery life on insulation and continuity tests.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• Backlight function to view the test results in dimly lit areas.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
• 3 functions in one unit, insulation test with 4 voltage ranges,
continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
Kyoritsu 3022A Insulation/Continuity Tester Memory function up to 99 data
•3 functions in one unit, insulation test with 4 voltage ranges, continuity test, AC voltage measurement
•200mA measuring current on continuity testing
•Comparator function with PASS / FAIL and buzzer
•0Ω adjustment at continuity measuring range
•Memory function up to 99 data
•Backlight LCD provides easy reading in dark locations
•Safety lock system prevents an erroneous operation on 500 and 1000 Volt ranges
•Safety standard IEC 61010-01 CAT.III 600V
• 3 functions in one unit, insulation test with 4 voltage ranges,
continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
(Photo: 3021)
• Extremely easy and simple operation
• Automatic ranges, indicated by individual LED's
• Newly-designed alligator clip
• It comes with a tough hard case
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
• Extremely easy and simple operation
• Automatic ranges, indicated by individual LED's
• Newly-designed alligator clip
• It comes with a tough hard case
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
(Photo: 3121B)
• Rugged design with a hard carrying case for field use
• Detachable High Voltage Line probe
• Automatic ranges, high and low scales, indicated by different LED's
• Drip proof
• Permits a wide range of insulation testing up to 100GΩ at variable test voltage from 1kV to 10kV.
• DC voltage output for recorders.
• Output voltage is shown on the digital display.
• After tests, automatically discharges the charges stored in the circuit under test.
• Operated by rechargeable Nickel-Cadmium batteries.
• Insulation Resistance up to 1TΩ
• Short-Circuit Current up to 1.5mA
• Wide Test Voltage from 250V to 5000V
• Diagnosis Function of PI and DAR
• Newly-designed alligator clip
• It comes with a tough hard case
• Filter function reduces noise interference for obtaining stable measurement
• Large display with Bar Graph indication and backlight
• Live voltage warning
• Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
• Short-Circuit Current up to 5mA
• Wide range measurements from 500V to 5000V and up to 1TΩ
• Large digital display with Bar Graph indication and white LED back light
• Polarization Index measurement (PI), Dielectric Absorption Ratio (DAR)
• Filter function reduces noise interference for obtaining stable measurement
• Indication of Output voltage and Discharge voltage
• Auto-discharge function and Output voltage warning function
• Auto power off and Battery Indicator
• Safety standard IEC 61010-1 CAT III 600V
• Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.
• Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.
• 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V
Fine adjustment of voltage setting at each range is also possible
• Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.
• Can be operated from built-in rechargeable battery or from AC line.
• Automatic discharge after test with monitoring of the discharge voltage.
• Internal memory can store about 43,000 data (max).
• Robust design for field use with IP64 rating (with lid closed).
The Model 3131A offers unmatched performance, and feature including test lead resistance zero adjustment for time-saving continuous operation, a clear ease to read illuminated scale, and a live circuit warning.
• Test insulation up to 100MΩ at 250V, 200MΩ at 500V, 400MΩ at 1000V and continuity up to 20Ω.
• LIVE circuit warning lamp plus audible warning.
• Automatic discharge of circuit capacitance when TEST button is released.
• Fuse protected (continuity range only).
• Battery check LED.
• Front panel zero adjust.
• Back light function to facilitate working at dimly lit situations.
• PRESS TO TEST button with lock down feature.
Analogue Insulation / Continuity Tester
•Dust and drip proof construction. (designed to IEC 60529 IP54)
•Designed to meet IEC 61010-1 and IEC 61557 safety standard.
•1mA rated test current at the minimum resistance.
•200mA measuring current on continuity testing.
•Automatic discharge of circuit capacitance.
(Any charge stored in the circuit under test will be automatically discharged after testing.)
•Live circuit warning buzzer and neon lamp.
•Small and lightweight. Shock resistant new case material.
•AC voltmeter with linear, easy-to-read scale.
•Operates on AA, R6 × 6 dry batteries.
Analogue Insulation / Continuity Tester
• Miniature lightweight insulation tester. It weighs only 340g(battery included),
but carries full measurement functions.
• Automatic discharge of circuit capacitance.
• Test leads with remote control switch.
• New robust housing case.
• Back light function.
• Neck strap for both hands operation
Analogue Insulation Tester
• 500V/1000MΩ(Model 3165)
• Expanded megohm scale for easy reading.
• New robust housing case to prevent damage.
• AC voltmeter scale for easy reading.
• Neck strap for both hand’s operation.
• 1000V/2000MΩ
• Expanded megohm scale for easy reading.
• New robust housing case to prevent damage.
• AC voltmeter scale for easy reading.
• Neck strap for both hand’s operation.
(Photo:3165)
Earth Resistance & Resistivity Tester
• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
Kyoritsu 4102A EARTH TESTER
• The latest circuit design permits the instrument to operate
with the minimum of influence from earth voltage
and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests
without tripping earth leakage current breakers
in the circuit under test.
• Lead wire connection to C and P terminals and proper
auxiliary earth resistance can be checked by "OK" lamp.
Lead wire connection to C and E terminals is good
when "OK" lamp is illuminated.
4102A-H Hard Case Model
• The latest circuit design permits the instrument to operate
with the minimum of influence from earth voltage
and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests
without tripping earth leakage current breakers
in the circuit under test.
• Lead wire connection to C and P terminals and proper
auxiliary earth resistance can be checked by "OK" lamp.
Lead wire connection to C and E terminals is good
when "OK" lamp is illuminated.
KYORITSU 4105A Digital Earth Tester Multimeter Resistance Meter
• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 15mA LOOP measurement:
LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).
The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).
• Direct reading of Prospective Short Circuit Current (PSC).
• Safe voltage measurement function.
• Large custom digital display readout on all models.
• Measure low loop resistances(resolution of 0.01Ω)
• Automatic lock-out if test resister overheats.
• Large custom digital display readout .
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating
• Complies with IEC 61557
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.
• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2
Various useful functions are available on Android devices using Bluetooth communication
• Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)
• Saved data includes measurement, GPS location and date & time Easy to check on map "When" and "Where" the measurement was made
• Comparator function on Android device informs when the measured value is lower/higher than the preset value
Earth /Ground resistance and Leakage current measurement functions
• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems
• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks
• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments
• Digital Light Meter
• 3 ranges changeable from low to high illuminance. (200/2000/20000lux)
• Data hold function.
• Digital light meter with separate light recieving sensor and meter.
• Accurate digital readout of tripping time.
• Two neon lamps give quick check for correct wiring.
• Compact, lightweight and simple to operate.
• Zero cross circuitry permits testing at 0 and 180 degree portion of sine wave. At these two tests minimum (best) and maximum (worst) trip times will be displayed.
• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 0 and 180 degree phase angle switch permits quick tests and consistent readings.
• Digital read-out of tripping time.
• Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
• Large custom digital display readout.
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating.
• Complies with IEC 61557
• Test of a large kind of RCD's: Standard, Selective, AC and A (DC sensitive breakers)
• Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at
× 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
• Measurement of trip out current
Measuring trip out current by varying current automatically.
• Remote Test
Enabling a user to hold the Test Leads with his both hands
by locking the Test Button. Measurement will automatically
start when the main voltage is detected.
• Voltage Measurement
Carrying out a constant measurement of voltage in the
stand-by mode at each Range.
• Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or
Protective conductors during RCD test - when applying
test currents - at measurement using EARTH in order to
prevent electrical shocks caused by the damaged earth.
Measurement will be ceased at AC50V or more.
• Dust- and Water-proof
Dust- and Water-proof construction
(designed to IEC 60529 IP54).
• Backlight
Facilitating working at dimly illuminated locations.
- Continuity Measurement
- Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display.
- Insulation Measurement
- Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display.
- Loop Impedance Measurement
- A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's.
- A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW 6016 allows also for phase to phase loop tests.
- PSC / PFC Measurement
- The Prospective Short Circuit Current (PSC) and Prospective Fault Current (PFC) are automatically calculated and shown on the display. As loop testing, the function has low and high test current options with the default to low current to avoid inadvertent tripping of RCDs.
- RCD Measurement
- The KEW 6016 has a comprehensive RCD test feature for RCD type AC (Alternative Currents), RCD type A (Pulsating Direct Currents), General and Selective (delayed).
- Measures at 1/2x, 1x, 5x of nominal RCD current. It also has Ramp Test and Auto test where all results are shown on one screen. Touch voltage limit can be selected for 25V or 50V depending on application.
- Earth Measurement
- Using the classical Volt-Amper method with two auxiliary earth spikes and without external power source. All test leads and spikes are supplied as standard accessories.
- Phase rotation
- KEW 6016 can check the phase rotation of three phase lines with clear indication of the sequence on the display.
- Voltage Measurement
- In addiction to the voltage measurement, this function gives also the Frequency of the voltage under test.
• Designed to meet IEC 61010-1 CAT III 600V
• Test leads with remote control switch.
(For insulation&Simplified Earth Test)
• Back light function.
• Color coded scales and range switch position for easy reading.
• Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
• Can be hung around the neck for both hand’s operation.
• Digital Phase Indicator with open phase checker
• Phase indicator designed to check the presence of open phase and also the phase sequence by LED and buzzer at the same time.
• Small, lightweight, and portable.
Kyoritsu 8031 Phase Indicator
• Digital Phase Indicator with open phase checker.
• Phase indicator designed to check the presence of open phase and also the phase sequence by LED and buzzer at the same time.
• Small, lightweight, and portable.
Kyoritsu 8031F 3 Phase Indication meter
• KEW8031F is designed to check phase sequence.
Lamps provided on the unit will also tell you if a phase is open.
• Can check a wide range of 3-phase power source from 110V to 600V.
Sealed against dust, the unit ensures trouble-free performance.
• Small, Lightweight and portable.
Designed for maximum ease of operation and ruggedness.
• No exposed metal parts, Safety features are incorporated including the instant push button switch operation.
• AC CLAMP ADAPTOR
• Model 8112 clamp adaptor is designed to be an AC current/voltage conversion probe capable of measuring AC current from 0.1mA to 120A in conjunction with digital multimeters.
Simple to operate, the unit has range switch position at 200mA,2A and 20A. It also features safety design throughout with no exposed metal parts.
• AC Clamp Adaptor
• Model 8112BNC is an AC clamp adaptor designed for use with oscilloscopes. Output cord has a BNC connector which enables direct observation of current waveform on oscilloscope. Refer to a diagram shown at left for application. Specifications are same as those for Model 8112.
• Permits extension of the AC and DC current ranges of almost any Digital Multimeters (DMMs) without breaking the circuit under test.
• Using KEW 8115 with KEW 1051/1052 (DMM) the display can be set for direct reading in A.
Kyoritsu KT170 KewTech Voltage Tester
• AC and DC voltage tests up to 690V with LED
• Comply with the latest standards IEC 61243 and IEC 61010
• Novel design
Large and bright LEDs: Values are visible in the dark place
Ergonomic design fits in the hand
• Two functions are available in one model
"Measurement without battery" and "Self Test (all LED on)"
• Test leads withstand harsh environments at low temperature
• Penlight (white LED)
• Auto-power ON/OFF
• Audible indication
• Variable test tips, φ2mm or φ4mm
• Probe protection cover can store the attachment of caps
• IP65 (IEC 60529)
Kyoritsu KT171 KewTech Voltage Tester
• AC and DC voltage tests up to 690V with LEDs and LCD
• Comply with the latest standards IEC 61243 and IEC 61010
• Novel design
Large and bright LEDs: Values are visible in the dark place
Ergonomic design fits in the hand
• Two functions are available in one model
"Measurement without battery" and "Self Test (all LED on)"
• Test leads withstand harsh environments at low temperature
• Penlight (white LED)
• Auto-power ON/OFF
• Audible indication
• Variable test tips, φ2mm or φ4mm
• Probe protection cover can store the attachment of caps
• IP65 (IEC 60529)
• Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above.
• Dual Display allows simultaneous measurements like Loop & PFC/PSC.
• Two wire connection for Loop L-L, L-N and PSC testing is possible.
• Phase rotation, Voltage and Frequency measurements.
• Lock-down test button for 'hands free' testing with auto-start operation.
• Display and front panel keyboards with Backlight to be visible in dark places.
• Water and Dust proof (IP54)
• Complies with IEC 61557
• Designed to IP 54 Rating
• Live circuit and wiring connection check LED's
• Triple ranges insulation tests at 250, 500 and 1000V
• Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip)
• Phase angle selection on RCD ranges
• Polarity switch for continuity tests
• Auto-null facility for continuity tests
• Earth probe for loop impedance testing on extraneous metalwork
• Contact Voltage Reading
• Test of a large kind of RCD's: Standard, Selective, AC and A
(DC sensitive breakers)
• Digital Phase Indicator with open phase checker.
• Phase indicator designed to check the presence of open phase and also the phase sequence by LED and buzzer at the same time.
• Small, lightweight, and portable.
• New technology permits safe testing, without the need of direct contact between probes and live wires.
• The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm.
• Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.
• The instrument can be fixed to a metal panel via the magnet on the back side.
• Wide measuring range for 3 phase installations from 70V to 1000V AC.
• Super brightness function permits clear LED's indication also in sunshine.
• Complies with IEC 61010-1 CAT IV 600V and CAT III 1000V.