checkout/checkout = http://www.hand-tools.com.my/cart account/register = http://www.hand-tools.com.my/register product/category = http://www.hand-tools.com.my/category product/search = http://www.hand-tools.com.my/search checkout/cart = http://www.hand-tools.com.my/checkout account/wishlist = http://www.hand-tools.com.my/wishlist product/product = http://www.hand-tools.com.my/product product/special = http://www.hand-tools.com.my/special information/information = http://www.hand-tools.com.my/information common/home = http://www.hand-tools.com.my
RM1,860.00
Fluke 117 Multimeter Elektrik Profesional | True RMS dengan Pengesan Voltan Tanpa Sentuhan Electrician’s Multimeter With Non-Contact Voltage
Price RM1,860.00
Product SKU Fluke 117
Brand Fluke
Availability In Stock
Shipping Fee
Quantity
Description

Fluke 117 Multimeter Elektrik Profesional | True RMS dengan Pengesan Voltan Tanpa Sentuhan Electrician’s Multimeter With Non-Contact Voltage

  • Fluke 117 multimeter Malaysia

  • Multimeter juruelektrik Fluke Malaysia

  • Alat ukur voltan tanpa sentuhan Malaysia

  • Multimeter digital Fluke True RMS Malaysia

  • Pembekal multimeter Fluke Malaysia

Specification / Spesifikasi Details / Butiran
Brand / Jenama Fluke
Model 117
Measurement Type / Jenis Ukuran True RMS AC/DC Voltage & Current
Special Feature / Ciri Istimewa Non-contact voltage detection (VoltAlert™)
Display / Paparan Large white LED backlight
Use / Kegunaan Electricians, facilities maintenance, HVAC, troubleshooting
Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Battery type 9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.