| Price | RM11,890.00 |
| Product SKU | FLUKE 1537 2500V Insulation Resistance Meter |
| Brand | Fluke |
| Availability | In Stock |
| Shipping Fee | |
| Quantity |
|
Description
FLUKE 1537 2500V Insulation Resistance Meter
Key Features:
- Selectable test voltages: 250 V, 500 V, 1000 V, and 2500 V.
- Insulation resistance measurement up to 500 GΩ.
- Automatic calculation of PI, DAR, and Dielectric Discharge (DD).
- Fine-tunable test voltages in 100 V increments.
- CAT IV 600 V rating for enhanced safety.
- Short circuit current of >5 mA for rapid, stable resistance measurements.
- Ramp Test Mode: Linearly increase test voltage to pinpoint faults.
- Built-in timer for controlled testing up to 99 minutes.
- Extensive data management: Store and review results or transfer data via PC software.
- Visual and audio continuity indicators for efficient troubleshooting.
- Supports up to 1,300 tests at 2500 V or 6,500 tests at 250 V on a single charge.
What's in the Box:
- Fluke 1537 Insulation Resistance Tester
- Test Leads
- Test Probes
- Alligator Clips
- User Manual
- 8 AA Alkaline Batteries
- PC Software for Data Management
Specifications:
General Specifications:
| Feature | Details |
|---|---|
| Display Size | 73.5 mm x 104 mm |
| Battery | 8 AA alkaline cells, IEC LR6 |
| Dimensions (H x W x L) | 184 mm x 211 mm x 93 mm |
| Weight | 1.3 kg |
| Operating Temperature | -10 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Humidity | ≤80 % RH (10 °C to 30 °C), ≤50 % RH (30 °C to 50 °C) |
| Altitude | Operating: 2000 m; Storage: 12000 m |
| Overvoltage Category | CAT IV 600 V |
| Safety | IEC 61010-1, Pollution Degree 2 |
| IP Rating | IEC 60529 IP40 |
Insulation Resistance Testing:
| Test Voltage | Range | Accuracy |
|---|---|---|
| 250 V | Up to 500 GΩ | ±5% |
| 500 V | Up to 500 GΩ | ±5% |
| 1000 V | Up to 500 GΩ | ±5% |
| 2500 V | Up to 500 GΩ | ±5% |
Additional Specifications:
- Leakage Current Measurement: 1 nA to 2 mA, ±20% accuracy.
- Capacitance Measurement: 0.01 μF to 2.00 μF, ±15% accuracy.
- Warning Range for Energized Circuits: >30 V.
- Short Circuit Current: >5 mA.
- Timer Range: 0 to 99 minutes, adjustable in 1-minute intervals.
- AC/DC Voltage Measurement: Up to 600 V (±2% accuracy).
- Resistance Measurement: Up to 60.00 kΩ (±2% accuracy).
Reviews (0)
view all
back
LatestMore
RM42.00
RM790.00
RM26.00
RM0.00
RM0.00
RM390.00
RM9,000.00
RM595.00
RM195.00
RM2,550.00
RM3,800.00
RM3,500.00
RM1,800.00
RM395.00
FeaturedMore
RM135.00
RM4,200.00
RM43.00
RM65.00
RM1,600.00
RM3,600.00
RM1,495.00
RM504.00
RM608.00
RM920.00
RM6,800.00
RM6,900.00
RM7,900.00
RM18,500.00
RM1,580.00
RM3,675.00
RM2,800.00